Workgroup Manager for AutoCAD系統(tǒng)配置

 昵稱9340 2006-07-25

安裝完Workgroup Manager for AutoCAD后,還需要配置3個文件。

1)wtcad.ini

2)wtacad.dmc

3)wtacad.map

1.      /Windchill/codebase/wmautocad/wtcad.iniffice‘‘ffice" />

WGM for AutoCAD配置文件,需要更改以下配置:

 

[DMS Integration]

...

DocumentLifecycle=CADDocLC

PartLifecycle=PartLCWithoutWf

link.drawings.to.parts=true

MultiplePartsOnDrawing=true

 

其它內(nèi)容均可以按缺省設(shè)置;

2.      /Windchill/codebase/wmautocad/wtacad.dmc

需要映射的屬性文件,更改后的文件內(nèi)容如下:

 

Windchill Workgroup Manager DMC, Revision 2.00

Generic

0

     1 SP:PART_NR                       U O T    200

     2 SP:PART_NAME                     U O T    200

     3 SP:DOC_NR                        U O T    200

     4 SP:DOC_NAME                      U O T    200

     5 GreeDrawingNo                    U O T    200

     6 GreeMaterial                     U O T    200

     7 GreeMaterialSpec                 U O T    200

 

您可以手工更改,但必須特別小心,一旦有特殊字符輸入,可能會導(dǎo)致失敗。

強(qiáng)烈推薦您使用Windchill提供的工具更改,請打開Windchill外殼程序,切換到Windchill\codebase\wmautocad目錄,執(zhí)行以下語句:

     windchill com.icubed.legend.dmc.ui.DMCCreate

然后輸入系統(tǒng)管理員的用戶名和密碼;

    

然后您可以在以下界面中直接添加需要映射的屬性;

    

添加完成后保存退出。

3.      /Windchill/codebase/wmautocad/wtacad.map

屬性的映射關(guān)系,更改后的文件內(nèi)容如下:

 

; wtacad.map

SP:PART_NR=CODE

SP:DOC_NR=CODE

SP:PART_NAME=PART_NAME

SP:DOC_NAME=PART_NAME

GreeDrawingNo=DRAWING_NUMBER

GreeMaterial=MATERIAL

GreeMaterialSpec=MATERIALSPEC

 

      這個文件只能手工輸入;

      第一行為注釋行;以后各行為內(nèi)容;

      等號左邊為Windchill中的屬性,右邊為AutoCAD中定義的屬性;

      其中,“SP:”開頭的表示Windchill的模型屬性,其它的則為軟屬性;

      SP:PART_NR 為部件編號,SP:PART_NAME為部件名稱;

      SP:DOC_NR CAD文檔編號,SP:DOC_NAMECAD文檔名稱;

 

特別提醒:每次更改配置后,需要重新生成wmautocad_config.jar文件。

Windchill外殼程序中執(zhí)行:

      windchill wt.tools.boot.MakeJar jar=wmautocad_config.jar


在Windchill PDMLink 8.0下,已經(jīng)取消DMCCreate工具,不需要使用該工具進(jìn)行處理。

wtacad.dmc文件的格式也已經(jīng)更改,如下所示:

Windchill Workgroup Manager DMC, Revision 2.00
Generic
0

; This is the I-Cubed Workgroup Manager DMC file. To disable the explicit setting of
; a Windchill system property by the Workgroup Manager, comment out the property with
; a semi-colon (;). It is not recommended to comment out any system properties marked
; as required.

; Description: Windchill WTPart Number
; Required/Optional: Required
     1 SP:PART_NR                       U O T    200
    
; Description: Windchill WTPart Name
; Required/Optional: Required
     2 SP:PART_NAME                     U O T    200
    
; Description: Windchill EPMDocument Number
; Required/Optional: Required
     3 SP:DOC_NR                        U O T    200
    
; Description: Windchill EPMDocument Name
; Required/Optional: Required
     4 SP:DOC_NAME                      U O T    200

; Description: Windchill EPMDocument Model Name
; Required/Optional: Required
     5 SP:CAD_NAME                      U O T    200

; Description: Windchill EPMDocument Iteration
; Required/Optional: Required if not using SP:ITERATION
     6 SP:DOC_ITERATION                 U O T    200

...

 

只需要把不需要映射的屬性前添加“;”注釋即可

在Windchill PDMLink 8.0中,需要映射的軟屬性不需要在wtacad.dmc文件中定義。
但需要把所有需要映射的軟屬性添加到類型管理器EPMDocument和WTPart的模板中,否則將導(dǎo)致屬性無法映射。

在Windchill PDMLink 7.0中,需要使用DMCCreate工具添加需要映射的軟屬性,但不需要在EPMDocument模板中定義就可以正常映射。